QINGDAO HIOUNCE HVAC EQUIPMENT CO.,LTD

Warm because of my existence, technology because of my appearance

Manufacturer from China
Active Member
3 Years
Home / Products / Gas Combi Boilers /

Low Nitrogen Wall Mounted Gas Boiler For Domestic Restaurant

Contact Now
QINGDAO HIOUNCE HVAC EQUIPMENT CO.,LTD
City:qingdao
Province/State:shandong
Country/Region:china
Contact Person:Mr.Chen Zong Hua
Contact Now

Low Nitrogen Wall Mounted Gas Boiler For Domestic Restaurant

Ask Latest Price
Video Channel
Brand Name :RENO
Model Number :L1PB20-42-A(F3) OPTIONAL
Certification :ISO14001,OHSAS18001,ISO9001,3C
Place of Origin :CHINA,QINGDAO
MOQ :Negotiable
Price :Negotiable
Payment Terms :L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability :10000pcs per month
Delivery Time :30days after receiving the deposit
Packaging Details :ach product in plastic bag which comes with the product instructions and foam packaging, then carton packaging outside with another thicker plastic bag.
Installation :HUNG on the wall
Appearance Material :Stainless Steel or Metal
Heat Power (KW) :20/24/26/28/32/40KW OPTIONAL
Gas style :NG/LPG
Surface Color :WHITE OPTIONAL
Name :USE NG/LPG WALL HUNG BOILER OR HEATER
Gas pressure(pa) :NG2000pa/LPG2800pa
Showing :LED Displayer Optional
Heat efficiency(%) :≥90
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Dual Function Hot Water Boiler Low Nitrogen Wall Mounted Gas Boiler For Domestic And Restaurant

GAS WALL HANGING BOILER INSTRUCTIONS

1. Safe and Reliable
With 21 kinds of safe protectionLow failure rate

2. Comfort
Ultra-quiet operationmore comfortable

3. Convenience
Touch controlmore precise

4. Environmental protection
Eenrgy saving and environmental protectionFollow the trend

5. After sale
7*24 after-sales service,worry free

8,Ultra-quiet operation and more comfortable

9,Constant temperature and efficient

11,Built-in temperature controller,7 days 24 hours timing editing function

12,Three-speed self-exhaust pumps,effectively improve the system efficiency

13,Imported chip,microcomputer control

14, 6 pipes brazing combined heat ex-changer

15,Digital display,more intuitive

16,Excellent instant heat type mode

TECHNICAL DATA OF GAS WALL HANGING BOILER

MODEL L1PB20-40-A(F3)

SPECIFICATIONS

A20-40-F3/B20-40-F3

RATED INPUT POWER(KW)

32-40 OPTIONAL

RATED OUTPUT POWER(KW)

18-36

THERMAL EFFICIENCY(%)

≥90

RATED VOLTAGE FREQUENCY(V/Hz/W)

220/230/50

GAS TYPE

NG/LPG

GAS PRESSURE(Pa)

2000/2800

TEMP.RANGE OF HEATING WATER(℃)

DHW:30-60 HEATING HOT WATER:30-80

△T=30℃ HOT WATER SUPPLY(KG/MIN)

8-16

APPLICATIVE WATER PRESSURE(MPA)

0.02-0.8
DIMENSION(HIGH*WIDE*THICK) 740*410*315
WEIGHT(KG) 30-41
DIAMETER OF SMOKE PIPEφ(COAXIAL) φ60/100































PRODECT DISPLAY
Function of expansion tank: It is used to absorb and compensate the expansion and shrinkage of water in the system, also used as system waters supply.
Low Nitrogen Wall Mounted Gas Boiler For Domestic Restaurant
The role of water pressure switch: In order to ensure the normal operation of the heating system, the system is filled with water, and maintain a certain pressure. The water shortage protection can be achieved by detecting the system pressure through the water pressure switch.

Low Nitrogen Wall Mounted Gas Boiler For Domestic Restaurant
The role of the air pressure switch: The air pressure switch is mainly responsible for the safety protection in the wall mounted furnace system. It is divided into two chambers by a valve inside, and the two chambers on both sides of the valve are respectively connected with two pressure measuring tubes. By comparing the pressure obtained by the pressure measuring tube, it can detect whether the smoke exhaust system is normal.
Low Nitrogen Wall Mounted Gas Boiler For Domestic Restaurant

The function of water flow switch: detect the amount of tap water through, under certain conditions, make the boiler switch to domestic hot water mode.

Low Nitrogen Wall Mounted Gas Boiler For Domestic Restaurant
The role of the main heat exchanger: the main heat exchanger is the part of heat exchange between the flue gas and the water in the system after the gas combustion. His appearance is thin fin, thickness and distance are set exactly as required. In the case of small boiler size requirements, to ensure sufficient heat exchange area and heat exchange efficiency. The surface of the heat exchanger is treated with high efficiency, which ensures the service life of the system.
Low Nitrogen Wall Mounted Gas Boiler For Domestic Restaurant
The role of the burner: It can ensure the normal combustion of gas, which from the nozzle high pressure injection into the burner inside the Venturi tube, causing the pressure in the tube down. Air (the first air) is inhaled and mixed with gas, Which will rush out gas hole to burn. The air that is still insufficient after the first mixing is partially mixed by the second mixing of air around the fire to form a complete combustion.


ABOUT US

Qingdao Hiounce hvac equipment co., Ltd., located in "brand, the beautiful coastal city - qingdao, China, was founded in the 1950s of the qingdao municipal restructuring state-owned enterprises - qingdao boiler factory. it is a company dedicated to research and development, production of high-grade wall hanging furnace, the electric heating furnace, biomass heating boiler, kitchen burning gas, discharge of oil absorption and the module of boiler fuel gas high-tech enterprises.

Qingdao Hiounce hvac equipment co., Ltd.have more than 100 employees.Company headquarters has total handling, personnel department, finance department, marketing department, the ministry of commerce, office (provincial), purchasing, and import and export department, technology department, engineering department, after-sales service department, and other functions of the eleven departments, through the perfect sales and service network, security, stability, energy saving, environmental protection products supply users.Low Nitrogen Wall Mounted Gas Boiler For Domestic Restaurant

Inquiry Cart 0